Welcome, Guest. Please Login or Register
Dynon Avionics, Inc.
 
Welcome to the Dynon Avionics forum!
  HomeHelpSearchLoginRegister  
 
 
Page Index Toggle Pages: 1
Send Topic Print
new owner of D-180 (Read 2965 times)
Aug 22nd, 2013 at 7:36pm

George Andre   Offline
Frequent Poster
I Am nuts for aeroplanes
St. Louis MO

Gender: male
Posts: 46
**
 
I have bought a plane with a D-180 that has been sitting for 2 years. It was initially installed around 2007 I do not take delivery for another few weeks so have nothing to look at and play with till then except this forum.
How can I immediately find the firmware status, once I have the hardware? I strongly suspect it is overdue for upgrade. And do I need to go back and install each upgrade or can I become up to date just by loading 5.5? thanks Cool
 
IP Logged
 
Reply #1 - Aug 22nd, 2013 at 10:52pm

Dynon Avionics   Offline
Dynon Official
Dynon Technical Support

Posts: 13203
*****
 
The version is under SETUP > VRSION, and you can just go right to 5.5.
 

Please do not use Private Messaging on form to contact. For private support:
Email: support at dynonavionics dot com
Phone: 425-402-0433 (7am-5pm Pacific weekdays)
IP Logged
 
Reply #2 - Aug 23rd, 2013 at 2:54pm

George Andre   Offline
Frequent Poster
I Am nuts for aeroplanes
St. Louis MO

Gender: male
Posts: 46
**
 
thanks...good news for me...
 
IP Logged
 
Reply #3 - Aug 24th, 2013 at 6:59am

Kevin D   Offline
New Member
I love flying!

Posts: 1
*
 
I have a Rotax 914 going in a Searey and ordered the matronics Fuelchec with transducer and purchased your transducer for second transducer- I now realize that they are different transducers - yours and theirs is a 201b- can I use theirs and yours or do I have to send one back. Can't get a response from Matronics yet
 
IP Logged
 
Reply #4 - Aug 26th, 2013 at 12:23pm

Dynon Avionics   Offline
Dynon Official
Dynon Technical Support

Posts: 13203
*****
 
They'll work together - you'll just need to make sure the K-factors for each are set correctly (which is usually 68000 for the redcube, and closer to 30000 (set per the tag) for the 201b.
 

Please do not use Private Messaging on form to contact. For private support:
Email: support at dynonavionics dot com
Phone: 425-402-0433 (7am-5pm Pacific weekdays)
IP Logged
 
Reply #5 - Aug 26th, 2013 at 12:53pm

Dynon Avionics   Offline
Dynon Official
Dynon Technical Support

Posts: 13203
*****
 
So to clarify - if you're using two fuel flow sensors with SkyView, you can input their different K-factors individually.

On re-reading this, it sounds like you're using the Matronics so that you can get differential fuel flows into a D180, D10, or D120. In that case, I think you'll need to use two of the same fuel flow sensors, as I don't think you can set the K-factors individually on the fuelcheck.
 

Please do not use Private Messaging on form to contact. For private support:
Email: support at dynonavionics dot com
Phone: 425-402-0433 (7am-5pm Pacific weekdays)
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print