V15.3.3 Sensor Settings (Read 298 times)
Mar 25th, 2018 at 7:05am

Michael FSGOM   Offline
Frequent Poster
I love flying!

Posts: 28
**
 
During update to this version, Skyview lost some customized sensor settings. After reload the archive seetings it works again:
Example of lost user sensor: Fuel preasure for Rotax engines:
c37_p8={
           valid=1
           name=FUEL
           id=Alex Road P906.B001.0S
           alarm_type=OFF
           range={
                 max_display=14.5038
                 min_display=0
                 range1_valid=1
                 range1_top=14.5038
                 range1_bot=10.8778
                 range1_name=R1
                 range1_color=RED
                 range2_valid=0
                 range2_top=7.25189
                 range2_bot=5.07632
                 range2_name=R2
                 range2_color=YELLOW
                 range3_valid=1
                 range3_top=10.8778
                 range3_bot=2.17557
                 range3_name=R3
                 range3_color=GREEN
                 range4_valid=0
                 range4_top=2.90075
                 range4_bot=2.17557
                 range4_name=R4
                 range4_color=YELLOW
                 range5_valid=1
                 range5_top=2.17557
                 range5_bot=0
                 range5_name=R5
                 range5_color=RED
                 }
           show_units=1
           }
« Last Edit: Mar 25th, 2018 at 7:05am by Michael FSGOM »  
IP Logged
 
Reply #1 - Mar 26th, 2018 at 6:00pm

Dynon Avionics   Offline
Dynon Official
Dynon Technical Support

Posts: 12963
*****
 
Just a note that if you're using custom engine definitions (ie, a custom .sfg file), you don't want to use our "method 1" update package, but instead use method 2 that lets you grab just the pieces you need - which is everything but the .sfg file. Unlike other configuration files, the .sfg file is loaded wholly and is not aggregated or concatenated. If you have custom sensors, method 1 will overwrite them with the latest revision of the factory definitions.
 

Please do not use Private Messaging on form to contact. For private support:
Email: support at dynonavionics dot com
Phone: 425-402-0433 (7am-5pm Pacific weekdays)
IP Logged
 