Added: CO Guardian support (Read 1016 times)
Apr 18th, 2018 at 6:09am

Maarten Versteeg   Offline
Frequent Poster
I love flying!

Posts: 29
**
 
Hello,
The latest edition (version AD) of the installation guide lists in the changes section that support was added for the CO Guardian monitor. I looked through the whole manual but couldn't find anything, neither terms CO (monitor), Guardian are mentioned anywhere in the installation manual. I like the idea of an CO monitor integrated with the Dynon product, but I am very curious what the support actually means in this case. Did anyone find some other explanation what this statement actually means?
Looking at the Guardian product line I could find a model 353N-201 that provides an 0-5 Volt analog output that can be used by an EFIS (e.g. Dynon), but that doesn't seen an adaptation that Dynon added. I would provide a continuous monitoring capability as long as one of the analog channels is available. That model also has a serial rs-232 interface but it doesn't document what this interface is generating, in any case serial interfaces being at premium doesn't seem an way to connect to the Dynon (my setup already uses all five (GPS, transponder, ADSB, COM2 and ELT).
 
IP Logged
 
Reply #1 - Apr 18th, 2018 at 10:35am

RayInGA   Offline
Expert
I love aviation!
Richmond Hill, GA

Gender: male
Posts: 532
*****
 
Being that it is listed under "Updated EMS Sensor Configuration file:," it would point to one of the EMS inputs being used to trigger a warning on the EFIS.

The Guardian site says it supports and external annunciator light, which the install drawing shows as 12 volt from the 2 amp CB (LED or similar). With that information, you should be able to set up a general purpose input and use the test feature of the CO detector to confirm proper operation.

You could have the annunciator light and use the spare relay output for the EFIS signal.
 

Ray Eaker
RV-7A flying since 27 Jan 2017
Dual Skyview 1000T with all available Dynon VFR goodies
IP Logged
 
Reply #2 - Apr 18th, 2018 at 11:12am

Steve W.   Offline
Expert

Posts: 1027
*****
 
I'd sure like to see a more complete interface solution for a remote CO detector than just a simple on-off indication.  If the Guardian box has serial comm, then it seems a perfectly natural implementation to figure out (with Guardian's engineers) how to hook it up so as to display actual PPM values for CO on a widget.
 
IP Logged
 
Reply #3 - Apr 18th, 2018 at 6:18pm

Maarten Versteeg   Offline
Frequent Poster
I love flying!

Posts: 29
**
 
Steve,
But the model 353N-201 has, besides the alarm relay and the rs232 connection, two analog outputs so as long as you have analog channels on the Skyview you can already display the percentage CO and the temperature, besides the alarm condition. It is just the rs232 that remains a mystery. The skyview woudl easily be able to check for a %CO limit, it jsut can't directly take the exposure duration into account, except for some delay in an alarm response,
- Maarten
 
IP Logged
 
Reply #4 - Aug 29th, 2018 at 3:07pm

Amuhs   Offline
Frequent Poster

Posts: 15
**
 
I have purchased and installed a Guardian 353D.  This is the new part number for the one that is compatible with Dynon. the old number was 353N.

I talked to the Guardian Engineer he believes that the Dynon software was modified some time last year so that you could define the 353D CO detector.  I went through all of the EMS input sensor possibilities  but could not find a way to add it so that I  can read the CO PPM. I can add a contact input that shows Safe or High.

I did not do anything with the serial inputs.

Is there going to be a software change that allows adding a CO input that displays CO PPM?
 
IP Logged
 
Reply #5 - Aug 29th, 2018 at 4:37pm

Steve W.   Offline
Expert

Posts: 1027
*****
 
Sure would like to have this capability (Dynon to CO detector via serial line, ability to display actual PPM and alarms...not just a relay alarm).

Seems like it'd be a simple thing to add, once you have the output data stream format from Guardian.
 
IP Logged
 
Reply #6 - Aug 29th, 2018 at 5:39pm

Dynon Avionics   Offline
Dynon Official
Dynon Technical Support

Posts: 13047
*****
 
If you have the latest software and the latest engine sensor definition file, you can hook up the CO Guardians that have an analog output (the Sport does, for example) to any of the four enhanced GP input. On those inputs, select pressure for type, and then you'll see it on the list.
« Last Edit: Aug 29th, 2018 at 5:42pm by Dynon Avionics »  

Please do not use Private Messaging on form to contact. For private support:
Email: support at dynonavionics dot com
Phone: 425-402-0433 (7am-5pm Pacific weekdays)
IP Logged
 
Reply #7 - Aug 30th, 2018 at 8:23pm

Amuhs   Offline
Frequent Poster

Posts: 15
**
 
I did as suggested in the previous post from Dynon and it worked.

On my skyview D37 connector I used pin 22.

I was told by Guardian to range it from 0 to 1000 PPM.

I set the normal level from 0 to 49 PPM. From 50 to 99 PPM I have it show yellow on the Dynon display which should correspond to the amber warning light on the 353. From 100 to 1000 PPM I have it show red which should correspond the red warning light on the 353.

When I push the test button on the 353 the displayed PPM increases enough so that the display turns red and I get an audible alarm in my headset.
 
IP Logged
 
Reply #8 - Oct 23rd, 2018 at 12:30pm

Roel Bergsma   Offline
New Member
I love flying!

Posts: 2
*
 
Hi all,

First of all, thank you all for trying to clear up the confusion around the CO Guardian integration with SkyView, but... I am still very confused and therefore would like to kindly ask if anyone can post a very clear 'manual' how to exactly connect a CO Guardian 353N-101 (currently sold as 353D-101) to your SkyView system.

I am totally confused what connection(s) and configuration are needed to my EMS (SV-EMS-220) and (one of) my serial ports on my PFD (SV-D1000T). I currently use both connections (I used the wiring diagram from the installation drawings of Guardian Avionics for the 353N-101, so I thought that would be OK):

Wired to my EMS:
- CO pin 3 ('CO 0-5V') wired to EMS C37 P31 ('CO PPM')
- CO pin 6 ('TEMP 0-5V') not (yet) connected

Wired to my PFD:
- CO pin 7 ('RS232 OUT') wired to PFD Serial Port 3 RX
- CO pin 8 ('RS232 IN') wired to PFD Serial Port 3 TX

Questions I have:
- Did I use the correct pin type on my EMS for the 'CO PPM'?

- Is it actually OK to wire the CO pins 7&8 to my Dynon's serial port?
- If yes, what should then be the settings (like baud rate, type of device in and out, etc.)? And how does it actually then work/operate?

- Is it recommendable to use 'CO TEMP' as well, wired through my EMS?
- If yes, what would be a correct EMS pin to wire it to?

It would really help if anyone can write a step by step instruction of how/what to wire to where and how to do the configuration of PFD and EMS?

Thank you, 'anyone', for your kind help!


 
IP Logged
 
Reply #9 - Oct 23rd, 2018 at 6:44pm

mmarien   Offline
Expert
Murray M.
Saskatoon SK CAN

Gender: male
Posts: 1179
*****
 
The RS232 connections won't work. Disconnect them when you get a chance. Your connection to EMS C37 P31 will work. You just need to set it up and add a gauge to one of your ENGINE pages.

If you have never added or modified an engine gauge you might want to read through the "EMS Sensor Definitions, Mapping, and Settings" in the Installation Guide. That will help you understand the following directions.

With Skyview ON, press and hold buttons 7 and 8 together to get into Skyview setup. Use EMS SETUP>SENSOR INPUT MAPPING to map pin C37p31 to the CO GUARDIAN and set the ranges with EMS SETUP>SENSOR SETUP. or

Copy the following text and save it to a TXT file called "CO.DFG". Put it on a thumb drive. Use SYSTEM SOFTWARE>LOAD FILES... Select the file you saved. It should report all lines loaded.

Code:
ems_module={
	c37_p31={
		valid=1
		name=CO PPM
		id=CO GUARDIAN 353N-201
		alarm_type=LATCHING
		range={
			max_display=200
			min_display=0
			range1_valid=1
			range1_top=49
			range1_bot=0
			range1_name=R1
			range1_color=GREEN
			range2_valid=1
			range2_top=99
			range2_bot=50
			range2_name=R2
			range2_color=YELLOW
			range3_valid=1
			range3_top=1000
			range3_bot=100
			range3_name=R3
			range3_color=RED
			range4_valid=0
			range4_top=13.5
			range4_bot=12
			range4_name=R4
			range4_color=GREEN
			range5_valid=0
			range5_top=12
			range5_bot=10
			range5_name=R5
			range5_color=YELLOW
			}
		show_units=0
		}
	}
 



Either way, use EMS SETUP>SCREEN LAYOUT EDITOR to add the CO PPM sensor to one or more of your engine pages.

You will get an ENGINE MONITOR alarm if the gauge goes into the red.
 

Glasair II FT - o320 - P-Mags - EFII - MTV 3 Blade CS - VP-X - Single 10" Skyview - Stratux Dual Band - zooooom ...
IP Logged
 
Reply #10 - Oct 24th, 2018 at 10:34am

GalinHdz   Offline
Senior Member
KSGJ/KBQN

Posts: 484
****
 
Does this work with all Guardian CO2 detector models (353-101, 353-201, 353D-101, etc) or just with a few specific ones?

Cool
 

N819PR
IP Logged
 
Reply #11 - Oct 24th, 2018 at 12:12pm

Steve W.   Offline
Expert

Posts: 1027
*****
 
So all of my Enhanced General Purpose Inputs are filled, but at least a couple of them could, I believe, be moved to regular GP inputs.  I have

Pin 8: Fuel Pressure Transducer
Pin 22: Fuel Level L (Capacitive to Voltage converter)
Pin 23: Roll Trim Position Potentiometer
Pin 31: Fuel Level R (Capacitive to Voltage converter)

I'm pretty sure FP and Roll Trim Pos can be moved, because Oil Press and Elevator Trim Pos are not on an Enhanced GP input.

Alternatively, does the CO Guardian *require* Enhanced GP?  Or will a regular GP input work?

And what's with the RS-232?  I presume it's useless because the SV doesn't know how to talk to the COG...
 
IP Logged
 
Reply #12 - Oct 29th, 2018 at 1:37pm

Steve W.   Offline
Expert

Posts: 1027
*****
 
mmarien wrote on Oct 23rd, 2018 at 6:44pm:
The RS232 connections won't work. Disconnect them when you get a chance. Your connection to EMS C37 P31 will work. You just need to set it up and add a gauge to one of your ENGINE pages.

If you have never added or modified an engine gauge you might want to read through the "EMS Sensor Definitions, Mapping, and Settings" in the Installation Guide. That will help you understand the following directions.

With Skyview ON, press and hold buttons 7 and 8 together to get into Skyview setup. Use EMS SETUP>SENSOR INPUT MAPPING to map pin C37p31 to the CO GUARDIAN and set the ranges with EMS SETUP>SENSOR SETUP. or

Copy the following text and save it to a TXT file called "CO.DFG". Put it on a thumb drive. Use SYSTEM SOFTWARE>LOAD FILES... Select the file you saved. It should report all lines loaded.

Code:
ems_module={
	c37_p31={
		valid=1
		name=CO PPM
		id=CO GUARDIAN 353N-201
		alarm_type=LATCHING
		range={
			max_display=200
			min_display=0
			range1_valid=1
			range1_top=49
			range1_bot=0
			range1_name=R1
			range1_color=GREEN
			range2_valid=1
			range2_top=99
			range2_bot=50
			range2_name=R2
			range2_color=YELLOW
			range3_valid=1
			range3_top=1000
			range3_bot=100
			range3_name=R3
			range3_color=RED
			range4_valid=0
			range4_top=13.5
			range4_bot=12
			range4_name=R4
			range4_color=GREEN
			range5_valid=0
			range5_top=12
			range5_bot=10
			range5_name=R5
			range5_color=YELLOW
			}
		show_units=0
		}
	}
 



Either way, use EMS SETUP>SCREEN LAYOUT EDITOR to add the CO PPM sensor to one or more of your engine pages.

You will get an ENGINE MONITOR alarm if the gauge goes into the red.


BTW, does this get you a display of the actual PPM values, or just a colored round widget?
 
IP Logged
 
Reply #13 - Oct 31st, 2018 at 3:48pm

mmarien   Offline
Expert
Murray M.
Saskatoon SK CAN

Gender: male
Posts: 1179
*****
 
If you use a bar or arc as the gauge it will display the PPM.
 

Glasair II FT - o320 - P-Mags - EFII - MTV 3 Blade CS - VP-X - Single 10" Skyview - Stratux Dual Band - zooooom ...