fuel flow (Read 227 times)
Jun 19th, 2018 at 2:32pm

steve izett   Offline
New Member
Perth Western Australia

Gender: male
Posts: 2
*
 
Hi there
Can I display 2 indepandent fuel flows from seperate transducers via the two sky view EMS inputs?
 
IP Logged
 
Reply #1 - Jun 19th, 2018 at 5:52pm

jakej   Offline
Expert
Australia

Gender: male
Posts: 1551
*****
 
Q - is it a dual SV Classic system or single screen ?
 
IP Logged
 
Reply #2 - Jun 19th, 2018 at 6:17pm

Dynon Avionics   Offline
Dynon Official
Dynon Technical Support

Posts: 12965
*****
 
Yes. There is a setting that you'll need to change manually:  ff_policy=single. You'll need to add this line to a file ending in .dfg, and then load it into SkyView. In this mode, you can use SkyView's two flow inputs to have independent flow gauges (instead of the normal subtraction scheme for engines with a return flow line).
 

Please do not use Private Messaging on form to contact. For private support:
Email: support at dynonavionics dot com
Phone: 425-402-0433 (7am-5pm Pacific weekdays)
IP Logged
 
Reply #3 - Jun 20th, 2018 at 6:39am

steve izett   Offline
New Member
Perth Western Australia

Gender: male
Posts: 2
*
 
I have 2 SV
Thanks very much. I'll update the file.
 
IP Logged
 