SV Classic Oil Temp Indication Issue (Read 166 times)
Oct 21st, 2018 at 12:54pm

John Korstian   Offline
New Member
Taildraggers Forever!
FW, Texas

Gender: male
Posts: 2
*
 
While flying my Kitfox SLSA today my digital oil temp seemed reasonable ~170 deg, but the analog slider was positioned over a black section of the tape below the yellow range. Any ideas?
 
IP Logged
 
Reply #1 - Oct 22nd, 2018 at 4:54pm

Dynon Avionics   Offline
Dynon Official
Dynon Technical Support

Posts: 13047
*****
 
When the engine type is set to Rotax 912, there are a couple of behaviors on the EMS page that you benefit from. Once is a variable redline that increases as the engine warms up. The other is a requirement that Rotax would like to see the oil temp get to near boiling every flight so cook off water that may have accumulated. Before you hit that number, moderate temperatures are colorless/black. When you get to the threshold (the start of that green), the rest of the gauge backfills in green.
 

Please do not use Private Messaging on form to contact. For private support:
Email: support at dynonavionics dot com
Phone: 425-402-0433 (7am-5pm Pacific weekdays)