Wierd amperage reading (Read 143 times)
Dec 1st, 2018 at 2:19pm

dahugo   Offline
Frequent Poster


Posts: 37
**
 
I have a D180 and installed the ammeter shunt in position A showing flow into and out of battery.  During a short flight today whike cycling thru the ems pages to monitor the system i noticed amps reading anywhere fron -99 to -60. The voltage looked fine so i assume it was some kinda anomoly. When i got on the ground and rechecked all readings were normal.

What could cause this reading?
 
IP Logged
 
Reply #1 - Dec 1st, 2018 at 3:51pm

jakej   Offline
Expert
Australia

Gender: male
Posts: 1577
*****
 
Most likely a bad electrical connection of the shunt to D180 wires particularly check out the crimps & fuses at the shunt end.
 
IP Logged
 
Reply #2 - Dec 3rd, 2018 at 5:39pm

Dynon Avionics   Offline
Dynon Official
Dynon Technical Support

Posts: 13064
*****
 
Yeah, first thing to do is to check the wiring to the shunt.
 